Beschrijving
Generator set controller module generator set parameter monitoring replaces hgm6120uc
Add power monitoring and power generation automatic switching control function (AMF). 2 LCD display with backlight, optional language interface, button operation. 3. Through the load test key, the controller can be placed in manual test mode. In this mode, when power generation is normal, the generator set will automatically run with load. 4Supports 8 languages (Chinese, English, Spanish, Russian, Portuguese, Turkish, Polish, French). 5Made of high-quality plastic materials, long service life and stable performance. Condition: Product Type: Generator Set Controller Material: Plastic Color: As shown in the figure Normal Mains Voltage Delay: (0-3600)S Mains Voltage Abnormal Delay: (0-3600s Mains Voltage Low Threshold: (30 -620)V Mains voltage high threshold: (30) 620)V Switching interval: (0-99.9)S Start-up delay: (0-3600)S Stop delay: (0-3600)S Start-up time: (1 -10) Warm-up time: (0-300)S Start-up time: (3-60)S Start-up interval time: (3-60)S Safe running time: (1-60)S Start-up idle time: (0-3600 )S High-speed preheating time: (0-3600)S High-speed cooling time: (0-3600)S Stop idle time: (0-3600)S Stop time: (0-120)S Waiting stop delay: (0- 120)S closing delay: (0-10)S number of engine teeth: (10-300) abnormal power generation delay: (0-20.0)S power generation overvoltage shutdown threshold: (30-620) V power generation undervoltage shutdown threshold : (30-620) V Under-speed shutdown threshold: (0-6000) Rpm Over-speed shutdown threshold: (0-6000) Rpm Under-frequency shutdown threshold: (0-75.0) Hz Over-frequency shutdown threshold: (0-75.0) Hz Over-temperature shutdown threshold: (80-140)C Low oil pressure shutdown adjustment value: (0-400) Kpa Low oil level threshold: (0-100) )% Speed signal loss delay: (0-20.0)S Charging failure threshold (0-30)V Battery Overvoltage Threshold: (12-40)V Battery Undervoltage Threshold: (4-30)V Installation Instructions: This instruction document provides a quick operating guide for the following situations: Using the DGS6100UC Series Controller . Please refer to the standard instructions for details. There are four models in the DGS6100U series, as follows: Model DGS6110U/6110UC is used for stand-alone automation control. DGS6120U/6120UC adds mains power monitoring and mains automatic switching control functions (AMF) Note 1: DGS6110UC/6120UC has an RS485 interface, while DGS6110U/6120U does not have an RS485 interface. Note 2: The following takes DGS6110UC/6120UC as an example. Key Function Stop/Reset Button In manual/automatic mode, the running generator set can be stopped. In the generator set alarm state, any shutdown alarm can be reset. In the shutdown state, press and hold this button for more than 3 seconds to test whether the panel indicator light is normal (light test). In the shutdown state, press this button again to stop quickly. Power button In manual mode or manual test mode, press this button to start the stationary generator set. Manual key Press this key to put the controller into manual mode. Auto key Press this key to put the controller into manual mode. Enter the automatic mode with load test button. Press this button to make the controller enter the manual test mode. In this mode, when power generation is normal, the generator set will automatically run with load. (DGS6110U does not have this function) c/O closing and opening key In manual mode, press this key to control the closing and opening of the switch. OK Set/Confirm key moves the cursor in parameter setting and confirms the setting information.
-
Fruugo-ID:
305898718-685301630
-
EAN:
6097172894845